LINAK

Linak Techline

Techline Actuators for Harsh conditions and heavy load. Techline improves your life by reassuring and help you succeed with reliable and precise movement designed for heavy duty industrial work situation.

LA10
  • Max lifting capacity: 3,500 N
  • No control box required
  • Modular and intelligent: connects in series
Data Sheet
LA12
  • Max Thrust: 750N
  • Max Speed: 40mm/s
  • Stroke Length: 19-130mm
Data Sheet
LA14
  • Max Thrust: 750N
  • Max Speed: 45mm/s
  • Stroke Length: 19-130mm
Data Sheet
LA18 IC Advanced
  • Max lifting capacity: 6,000 N
  • Supports favourite positions
  • Connects massage motors directly
Data Sheet
LA18 IC Standard
  • Max lifting capacity: 6,000 N
  • Wireless communication
  • Quiet and powerful
Data Sheet
LA20
  • Max Thrust: 2,500N
  • Max Speed: 8.9mm/s
  • Stroke Length: 20-300mm
Data Sheet
LA23
  • Max thrust: 2,500N
  • Max Speed: 22mm/s
  • Stroke Length: 20-300mm
Data Sheet
LA23 Deskline
  • Max thrust: 2,500N
  • Small and compact actuator
  • compatible with cbd6s
  • Stroke Length: 20-300mm
Data Sheet
LA25
  • Max thrust: 2,500N
  • Max Speed: 25mm/s
  • Stroke Length: 20-300mm
Data Sheet
LA27
  • Max thrust: 6,000N
  • Max Speed: 25mm/s
  • Stroke Length: 20-300mm
Data Sheet
LA27 Homeline analogue
  • Powerful Linear Actuator
  • For Head and Foot adjustment
  • compatible with CBH
LA27 Homeline Hall Senor
  • Powerful Linear actuator
  • For back/leg/neck/foot-Adjustment
  • Compatible with CBH A
LA28
  • Max thrust: 3,500N
  • Max Speed: 46mm/s
  • Stroke Length: 100-600mm
Data Sheet
LA28
  • Max thrust: 3,500N
  • Max Speed: 46mm/s
  • Stroke Length: 100-600mm
Data Sheet
LA29
  • Max thrust: 6,000N
  • Max Speed: 29.6mm/s
  • Compact design
  • Stroke Length: 100-300mm
LA30
  • Max thrust: 6,000N
  • Max Speed: 65mm/s
  • Stroke Length: 50-400mm
Data Sheet
LA31 Careline
  • Max thrust: 6,000N(push)
  • (4,000N pull)
  • Max Speed: 65mm/s
  • Stroke Length: 50-400mm
Data Sheet
LA31 Deskline
  • Quiet & Powerful Actuator
  • Max thrust: 3,500N
  • Max Speed: 20mm/s
  • Stroke Length: 100-500mm
Data Sheet
LA32
  • Max thrust: 6,000N
  • Max Speed: 15mm/s
  • Stroke Length: 100-400mm
Data Sheet
LA33
  • Max thrust: 6,000N
  • Max Speed: 15mm/s
  • Stroke Length: 100-600mm
  • Data Sheet
LA34
  • Max thrust: 10,000N
  • Max Speed: 18mm/s
  • Stroke Length: 100-600mm
Data Sheet
LA35
  • Max thrust: 6,000N
  • Max Speed: 19.5mm/s
  • Stroke Length: 100-600mm
Data Sheet
LA36
  • Max thrust: 10,000N
  • Max Speed: 160mm/s
  • Stroke Length: 100-999mm
Data Sheet
LA37
  • Max thrust: 15,000N
  • Max Speed: 3.5mm/s
  • Stroke Length: 100-600mm
Data Sheet
LA40
  • Max thrust: 8,000N
  • Max Speed: 16mm/s
  • IPX6 Washable DURA
  • Stroke Length: 50-405mm
Data Sheet
LA44
  • Max thrust: 12,000N (Push)
  • Max Speed: 14mm/s
  • Stroke Length: 100-400mm
Data Sheet

ACCESSORIES

TR-EM-322 BASIC
  • Power supply: 230Vac ±20%
  • Max effect P In: 125W (20% intermittens)
  • Battery back-up: VRLA battery 12V - 0.8 A/h
  • The position of the actuator spindle (stroke length) is determined by a 0-10V (2-10V) signal emitted by an automatic system.
TR-EM-208 - Single motor control unit
  • TR-EM-208 is a motor control unit designed for operation of a single actuator.
  • It is also possible to adjust soft start and soft stop
  • Power supply: 12-35 V DC (ripple max. 30%) Max. power limit: 12 A cont. 25 A (25% ON / 75% OFF)
TR-EM-239 - Parallel motor control unit
  • Actuator connection: 2 actuators
  • Actuator power limit: 2 x 10 A intermit. 100 % 2 x 20 A inter mit. 25%
  • Actuator voltage: 24 Vdc
  • Supply voltage to PCB: 12 - 35 V DC
  • Power limit, setting: 1 - 20 A
TR-EM-273 - Parallel motor control unit
  • Actuator connection: 4 actuators
  • Actuator power limit: 4 x 15 A intermit. 50%, 4 x 25 A intermit. 20%
  • Actuator voltage: 24 Vdc
  • Supply voltage to PCB: 10 - 35 V DC
  • Power limit, setting: 1 - 20 A
TP 1 - Waterproof control
  • The TP 1 is a waterproof desk switch made for rough working conditions.
  • Protection rating: IP66
  • Colour: Black/Grey
Direct change switch (Rocker)
  • Function: Change over switch with off position in the center
  • IP degree: up to IP65 - mounted in a box
Switching Supply UHP-500
  • Power supply: 90 - 246 V AC; 47-63 Hz
  • Output voltage: 24 V DC (22,8 - 25,2 V)
  • Max power: 20 AMP
Battery Backup (WCU-UPS)
  • Supply: 23-34 VDC
  • Power consumption with supply voltage connected: Max. 0.9 A on charging, 0.25 mA on standby

Function Test

Climatic Tests :

In the climatic test the actuator are tested to operate in extreme temperature as well as to endure rapid changes in temperature, In Some tests, the actuator has to withstand going from a +100 deg C environment To 30 deg C repeatedly and still maintain full functionality

Mechanical Tests :

Vibration:The actuator must withstand continuous vibration in three direction

Shock: The shock test puts the actuator through 3 shocks of uo to 100 G in each of six direction

Bumps: The actuator receives bumps of up to 40 G in each of six direction several hundred times

Electric Test:

All the electric parts are tested i.e power supply, power and signal cables, Control Signals etc. Electrical immunity is tested according to industrial standards i.e for radio noise, electrical discharge and burst.

Application

Extreme testing

Contact Us

9566006666